Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Optimisation of laser and mass spectrometer parameters for the<i>in situ</i>analysis of Rb/Sr ratios by LA-ICP-MS/MS

Loading...
Thumbnail Image

Authors

Gorojovsky, Lauren
Alard, Olivier

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

The Rb-Sr isotopic system is widely used in geochronology. Conventionally burdened by the isobaric overlap of(87)Rb and(87)Sr, Rb/Sr datingin situhas only recently become achievable with the newly developed LA-ICP-MS/MS system. Simultaneous use of reactive gas (e.g.O-2, N2O, or CH3F) during LA-ICP-MS/MS analysis has been shown to resolve the Rb and Sr overlap, thus now making available key spatial and temporal information that can only be accessedvia in situanalytical techniques. The accuracy and precision of Rb/Sr ratios and ages are largely dependent on the laser and ICP-MS/MS parameters used. Rb/Sr isotopic analysis by LA-ICP-MS/MS is a recently developed technique and these parameters are yet to be fully explored. We investigate the effects of laser wavelength (213 nm and 193 nm), laser frequency (5 Hz and 10 Hz), laser carrier gas (He, H-2, and N-2), dwell time, and external standard calibration on the accuracy and precision of(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios and ages. These analytical conditions have been tested on the commercially available reference materials: NIST SRM 610, USGS BHVO-2G, and pressed nano-particulate powder tablet CRPG Mica-mg, as well as a Monastery phlogopite megacryst. Our results show that accuracy and precision for(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios are significantly affected by laser wavelength and frequency. Variation in these parameters can strongly magnify any matrix effects which directly influences the ability to apply effective external corrections. We obtain the best accuracy and precision when using a 193 nm laser wavelength, ablating at a frequency of 5 Hz (0.30 2s% and 0.15 2s% for(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios, respectively). Meanwhile we find that age accuracy is highly dependant on external reference materials. When these analytical settings are put to test on the Monastery phlogopite, we obtain an age of 90.0 +/- 3.6 (0.24% accuracy) when using mica-mg (Rb-87/Sr-86) and NIST 610 (Sr-87/Sr-86) as external standards.

Description

Citation

Source

Journal of Analytical Atomic Spectrometry

Book Title

Entity type

Publication

Access Statement

License Rights

Restricted until