Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Passivation of iron in pH buffered solutions with and without chloride ions

Loading...
Thumbnail Image

Date

Authors

Bosco, I.
Cole, I.
Forsyth, M.

Journal Title

Journal ISSN

Volume Title

Publisher

Australasian Corrosion Association

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

Interaction with the chloride ions can significantly cripple the service life of steel structures. It is therefore necessary to understand the impact of chloride ions on the kinetics of iron passivation. In order to firstly estimate the pH-potential region for iron passivation, potentiodynamic polarisation tests were carried out in borate buffer solutions at different pH. The optimum condition to achieve passivation was subsequently found to be in a solution having pH 9 with the electrode potential in the range 0.5 to 0.8 VSCE. The influence of chloride ions on iron passivation was then studied under these conditions by performing chronoamperometry. These experiments were carried out in different solutions at pH 9 with/without borate buffer, both in the presence and absence of chloride ions. In general, passivity, which is manifested by the drop of the chronoamperometric currents from millamperes to few microamperes, was immediately acheived in chloride-free borate solutions (in a few seconds). In non-borate solutions with chlorides, passivity was not achieved even after many hours of chronoamperometry. In borate buffered solutions with the chlorides added, the chronoamperometric currents dropped to a few 100s of microamperes with time, implying that a less protective passive film forms on steel. These results have been discussed in the context of passivity breakdown in the presence of chlorides and local acidification.

Description

Citation

Source

Book Title

Annual Conference of the Australasian Corrosion Association 2013: Corrosion and Prevention 2013