Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Oriented Circular Dichroism Spectroscopy

dc.contributor.authorRodger, Alisonen
dc.coverage.spatialBerlin, Heidelbergen
dc.date.accessioned2026-01-02T08:41:26Z
dc.date.available2026-01-02T08:41:26Z
dc.date.issued2013en
dc.description.abstractSynonyms OCD Definition Oriented circular dichroism (OCD) spectroscopy, as the name implies, is the circular dichroism spectroscopy of oriented samples. It can be a very useful technique; however, it is prone to artifacts resulting from linear dichroism contributions to the observed spectrum (Nordén et al. 2010). Thus care must be taken in collecting and analyzing the data. A sample for OCD should be symmetric about a unique orientation axis. Data must then be collected with the light propagating along that unique axis and spectra measured at different rotations about the unique axis compared. If the rotated spectra are the same, then these data can be believed. If the sample is perfectly oriented (as it would be in a perfectly oriented crystal but probably in no other method), the observed spectrum is then equivalent to three times (no rotational averaging) the CD spectrum of all the transitions in an isotropic sample except those polarized along the unique axis (which are invisible).en
dc.description.statusPeer-revieweden
dc.format.extent2en
dc.identifier.isbn9783642167119en
dc.identifier.isbn9783642167126en
dc.identifier.otherORCID:/0000-0002-7111-3024/work/189446918en
dc.identifier.scopus105011794334en
dc.identifier.urihttps://hdl.handle.net/1885/733802132
dc.language.isoenen
dc.publisherSpringer Science+Business Media B.V.en
dc.relation.ispartofEncyclopedia of Biophysicsen
dc.titleOriented Circular Dichroism Spectroscopyen
dc.typeBook chapteren
dspace.entity.typePublicationen
local.bibliographicCitation.lastpage1809en
local.bibliographicCitation.startpage1808en
local.contributor.affiliationRodger, Alison; University of Warwicken
local.identifier.doi10.1007/978-3-642-16712-6_639en
local.identifier.pure01be8ff2-b7ec-4f52-a6fe-bd207ca7b86ben
local.identifier.urlhttps://www.scopus.com/pages/publications/105011794334en
local.type.statusPublisheden

Downloads