Open Research will be updating the system on Tuesday, 14 July 2026, from 8:15 to 9:00 AM. We apologise for any inconvenience caused.

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Visualization and thermometry in hypersonic wedge and leading-edge separated flows

Loading...
Thumbnail Image

Date

Authors

Kaseman, T.
Le Page, L. M.
O’Byrne, S.
Gai, S. L.

Journal Title

Journal ISSN

Volume Title

Publisher

American Institute of Aeronautics and Astronautics Inc.

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

This paper presents preliminary nitric oxide planar laser-induced fluorescence (NO- PLIF) measurements of rotational temperature in hypersonic flow for a 30° wedge and a leading-edge separation (tick-mark shaped: 3) model. The experiments were conducted in the T-ADFA free-piston shock tunnel at two flow conditions with specific enthalpies of 3:1MJ=kg and 11:3MJ=kg. For the wedge, thermometry was done at the low-enthalpy condition to validate the performance of the PLIF system and image processing method. The freestream temperature and shock angle are both in good agreement with the predicted flow conditions, but the post-shock temperature is 300K lower than expected. Additionally, there is a 50% increase from the nominal freestream temperature as the flow travels towards the shock wave, which affects approximately 5mm upstream of the shock. Both the low post-shock and high freestream temperatures are linked to fluorescence bleed, where high fluorescence signal from one side of the shock increases signal on the other side, introducing an error in the calculated temperature. For the tick model, PLIF visualization was done at the low-enthalpy condition and PLIF thermometry was done at the high-enthalpy condition. Comparison between the tick images at the two conditions shows that the recirculation bubble size is larger and the wake neck further downstream for the low-enthalpy condition. At the high-enthalpy condition, the freestream temperature was 150K lower than the predicted value and the temperatures in the recirculation bubble and recompression region have uncertainties up to 60% of the local temperature caused by low signal-to-noise ratio.

Description

Keywords

Citation

Source

Book Title

AIAA SciTech Forum - 55th AIAA Aerospace Sciences Meeting

Entity type

Publication

Access Statement

License Rights

Restricted until

abcd