Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Experimental apparatus for studying the corrosion of materials in high-temperature liquid sodium for nuclear and solar thermal research - corrosion analysis of sodium exposed 316 L stainless steel at 650 °C

Loading...
Thumbnail Image

Date

Authors

Sarvghad, Madjid
Naylor, Daniel
Ong, Teng Cheong
Bell, Stuart
Will, Geoffrey
Taheri, Mahdiar
Coventry, Joe
Steinberg, Theodore A.

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

With the growing interest in testing liquid metals, such as sodium, for nuclear or concentrated solar power applications, two new experimental apparatuses were designed and custom-built to conduct static and dynamic corrosion testing. These apparatuses aid in characterizing high temperature sodium compatibility with structural alloys, under controlled conditions. The static system design offers several advantages, including effective sodium vapor management, controlled oxygen levels, and the ability to conduct long-term corrosion testing of multiple samples at temperatures up to 760 °C. The dynamic test loop is designed to allow for continuous testing up to 800 °C, cycling testing with a heating/cooling capacity of 8 kW, impurity control and monitoring via a cold trap and plugging meter. To demonstrate the utility of the static testing system, corrosion of 316 L Stainless Steel alloy in liquid sodium containing 3 ppm and high oxygen levels was investigated at 650 °C for 340–504 h and compared to the literature. After exposure, the samples were characterized by scanning electron microscopy coupled with energy dispersive x-ray spectroscopy. In agreement with the literature, our results show a significant reduction in corrosion damage under low-oxygen conditions and confirm the functionality of the designed test apparatus for sodium corrosion investigations in static systems. The dynamic system is operational, but yet to be deployed for corrosion tests.

Description

Citation

Source

Nuclear Engineering and Design

Book Title

Entity type

Publication

Access Statement

License Rights

Restricted until