Michelmore, AndrewCharles, ChristineBoswell, RoderickShort, RobWhittle, Jason D2015-12-131944-8244http://hdl.handle.net/1885/74529External parameters (RF power and precursor flow rate) are typically quoted to define plasma polymerization experiments. Utilizing a parallel-plate electrode reactor with variable geometry, it is shown that these parameters cannot be transferred to reactoKeywords: functional retention; Intrinsic parameters; Ion fluxes; Parallel-plate electrodes; Plasma polymer films; Polymerization process; Power coupling efficiency; Precursor flow rates; Deposition rates; Geometry; Ions; Polymer films; Plasma polymerization deposition rate; functional retention; ion flux; plasma polymerizationDefining plasma polymerization: New insight into what we should be measuring201310.1021/am401484b2016-02-24