Effect of conical cut-out turbulators with internal fins in a circular tube on heat transfer and friction factor

dc.contributor.authorMuthusamy, C
dc.contributor.authorVivar, Marta
dc.contributor.authorSkryabin, Igor
dc.contributor.authorSrithar, K
dc.date.accessioned2015-12-13T22:23:13Z
dc.date.issued2013
dc.date.updated2016-02-24T09:10:05Z
dc.description.abstractHeat transfer, friction factor and thermal performance factor characteristics in a circular tube fitted with conical cut-out turbulator integrated with internal fins are investigated for three pitch ratios (PR) 3, 4, 5 and tested with two different arrang
dc.identifier.issn0017-9310
dc.identifier.urihttp://hdl.handle.net/1885/72662
dc.publisherElsevier
dc.sourceInternational Journal of Heat and Mass Transfer
dc.subjectKeywords: Air heater; Circular tubes; Desalination systems; Friction factors; Heat Transfer enhancement; Turbulators; Desalination; Fins (heat exchange); Forced convection; Humidity control; Mixed convection; Nusselt number; Reynolds number; Specific heat; Water fi Air heater; Conical turbulators; Flow through circular tubes; Friction factor; Heat transfer enhancement; Humidification-dehumidification desalination system
dc.titleEffect of conical cut-out turbulators with internal fins in a circular tube on heat transfer and friction factor
dc.typeJournal article
local.bibliographicCitation.lastpage68
local.bibliographicCitation.startpage64
local.contributor.affiliationMuthusamy, C, Thiagarajar College of Engineering
local.contributor.affiliationVivar, Marta, College of Engineering and Computer Science, ANU
local.contributor.affiliationSkryabin, Igor, College of Engineering and Computer Science, ANU
local.contributor.affiliationSrithar, K, Thiagarajar College of Engineering
local.contributor.authoruidVivar, Marta, u4700670
local.contributor.authoruidSkryabin, Igor, u4327298
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor160510 - Public Policy
local.identifier.absfor090600 - ELECTRICAL AND ELECTRONIC ENGINEERING
local.identifier.ariespublicationf5625xPUB3366
local.identifier.citationvolume44
local.identifier.doi10.1016/j.icheatmasstransfer.2013.03.004
local.identifier.scopusID2-s2.0-84877142475
local.identifier.thomsonID000320287400010
local.type.statusPublished Version