Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

A new value for the half-life of 10Be by Heavy-Ion Elastic Recoil Detection and liquid scintillation counting

Loading...
Thumbnail Image

Date

Authors

Korschinek, Gunther
Bergmaier, A
Feastermann, T
Gerstmann, U. C
Knie, K
Rugel, G
Wallner, Anton
Dillmann, I
Dollinger, G
Lierse von Gostomski, Ch.

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

The importance of 10Be in different applications of accelerator mass spectrometry (AMS) is well-known. In this context the half-life of 10Be has a crucial impact, and an accurate and precise determination of the half-life is a prerequisite for many of the applications of 10Be in cosmic-ray and earth science research. Recently, the value of the 10Be half-life has been the centre of much debate. In order to overcome uncertainties inherent in previous determinations, we introduced a new method of high accuracy and precision. An aliquot of our highly enriched 10Be master solution was serially diluted with increasing well-known masses of 9Be. We then determined the initial 10Be concentration by least square fit to the series of measurements of the resultant 10Be/9Be ratio. In order to minimize uncertainties because of mass bias which plague other low-energy mass spectrometric methods, we used for the first time Heavy-Ion Elastic Recoil Detection (HI-ERD) for the determination of the 10Be/9Be isotopic ratios, a technique which does not suffer from difficult to control mass fractionation. The specific activity of the master solution was measured by means of accurate liquid scintillation counting (LSC). The resultant combination of the 10Be concentration and activity yields a 10Be half-life of T1/2 = 1.388 ± 0.018 (1 s, 1.30%) Ma. In a parallel but independent study (Chmeleff et al. [11]), found a value of 1.386 ± 0.016 (1.15%) Ma. Our recommended weighted mean and mean standard error for the new value for 10Be half-life based on these two independent measurements is 1.387 ± 0.012 (0.87%) Ma.

Description

Citation

Source

Nuclear Instruments and Methods in Physics Research: Section B

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31
abcd