The effect of post-cure duration on the mode I interlaminar fracture toughness of glass-fibre reinforced vinylester
Loading...
Date
Authors
Tucker, R
Compston, Paul
Jar, P-Yue
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier
Abstract
The effect of different post-cure conditions on the mode I fracture toughness of a vinylester resin and its glass-fibre reinforced composite counterpart has been studied. Two sets of parameters were investigated. The first was the post-cure duration at constant temperature; 90 °C for 1, 4 and 24 h. The second, for resin toughness only, was a combination of post-cure temperature and duration; 90 °C/4 h, 80 °C/8 h and 70 °C/16 h. The results show that the post-cure increases toughness. This trend is consistent between the pure resin and the fibre composite for all treatments, except at 90 °C/24 h. It is believed that the prolonged post-cure duration of 24 h has weakened the bond strength at the fibre-matrix interface, thus reducing the effectiveness of toughness transfer from the matrix to the composite. The study concludes that the post-cure enhances the toughness of the glass-fibre/vinylester composite, mainly due to the increase of resin toughness.
Description
Citation
Collections
Source
Composites Part A: Applied Science and Manufacturing
Type
Book Title
Entity type
Access Statement
License Rights
Restricted until
2037-12-31