Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Validation of a method to measure three-dimensional hip joint kinematics in subjects with femoroacetabular impingement

Loading...
Thumbnail Image

Date

Authors

Ward, Thomas
Hussain, Mafruha M.
Pickering, Mark
Perriman, Diana
Burns, Alexander
Scarvell, Jennifer M
Smith, Paul

Journal Title

Journal ISSN

Volume Title

Publisher

Wichtig Publishing

Abstract

Introduction:A kinematic measurement method combining dynamic motion and imaging, which captures the behaviour of the hip at terminal motion, may offer improved diagnostic accuracy and enhance our understanding of the mechanics of femoroacetabular impingement (FAI). Methods:3 embalmed cadaveric hip/pelvis specimens with implanted Roentgen Stereophotogrammetric Analysis (RSA) beads were mounted on a custom rig and imaged with a fluoroscope in four poses to simulate a clinical impingement examination: in hip extension and in three positions: near impingement, early impingement and late impingement while simulating a flexion/adduction/internal rotation manoeuvre. Hip joint kinematics were measured using 2 methods and compared: RSA (gold standard) and a custom 3-dimensional to 2-dimensional (3D–2D) image registration method which matches 3D models developed from CT to 2D fluoroscopic images. Results:Using RSA as the gold standard, bias and precision of hip joint rotations measured using 3D–2D registration demonstrated maximums of 1.64° and 3.96°, respectively. However, if the single outlier was removed, bias and precision were 0.55° and 1.38°. Bias and precision of translations had maximums of 0.51 mm and 0.77 mm, respectively. Conclusions:This 3D to 2D registration method may offer a clinically useful solution for dynamic assessment of hip impingement. If 5-mm translation and 10° of rotation represent a clinically significant difference in hip kinematics, the method’s accuracy of approximately 1 mm displacement and 1° rotation should enable detection of significant clinical differences.

Description

Citation

Source

HIP International

Book Title

Entity type

Access Statement

License Rights

Restricted until

2099-12-31