Inter-visit Test-retest Variability of the Topcon 3D OCT-2000 in Glaucoma

dc.contributor.authorPearce, John
dc.contributor.authorMaddess, Ted
dc.date.accessioned2021-07-14T01:25:37Z
dc.date.issued2017
dc.date.updated2020-11-23T10:42:08Z
dc.description.abstractPurpose. To determine the inter-visit test-retest variability (TRV) of a spectral domain optical coherence tomograph, the Topcon 3D OCT-2000, in the measurement of optic nerve head topography, peripapillary retinal nerve fiber layer (pRNFL), and macular ganglion cell complex (GCC) parameters in glaucoma patients.We also examine whether TRV with this instrument varies with the extent of glaucomatous damage. Methods. Twenty-four subjects with varying degrees of glaucoma severity provided 41 eyes with usable results for the study. 3D Disc Retinal Nerve Fiber Layer Analysis and Macula V (GCC) scans were repeated 1 week apart, at the same time of day, to determine the inter-visit TRV. TRV was determined using Bland-Altman limits of agreement (LoA) and the resulting coefficients of repeatability (CR). Results. The overall horizontal and vertical cup/disc ratio CRs were 0.05 and 0.07, respectively. The GCC CR was 2.9 Km. In contrast, average pRNFL TRV expanded with increasing damage, with the LoA being well fitted by T(34.67 j 0.294(d)), where d is the pRNFL thickness. A more complex model, with constant LoA of T5.61 Km at d 982 Km, and linearly expanding TRV below that, achieved marginal significance (p G 0.06). Conclusions. The repeatability of GCC measurements with this instrument was excellent. The determination of statistically significant change in average pRNFL should take into account average pRNFL thickness. (Optom Vis Sci 2017;94:00Y00)en_AU
dc.description.sponsorshipThis research was supported by the Australian Research Council through the ARC Centre of Excellence in Vision Science (CE0561903) and the Australian Federal Government through the Nursing and Allied Health Scholarship Support Schemeen_AU
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.issn1040-5488en_AU
dc.identifier.urihttp://hdl.handle.net/1885/240572
dc.language.isoen_AUen_AU
dc.publisherLippincott Williams & Wilkinsen_AU
dc.relationhttp://purl.org/au-research/grants/arc/CE0561903en_AU
dc.rights© 2016 American Academy of Optometryen_AU
dc.sourceOptometry and Vision Scienceen_AU
dc.titleInter-visit Test-retest Variability of the Topcon 3D OCT-2000 in Glaucomaen_AU
dc.typeJournal articleen_AU
local.bibliographicCitation.issue3en_AU
local.bibliographicCitation.lastpage410en_AU
local.bibliographicCitation.startpage404en_AU
local.contributor.affiliationPearce, John, College of Health and Medicine, ANUen_AU
local.contributor.affiliationMaddess, Ted, College of Health and Medicine, ANUen_AU
local.contributor.authoruidPearce, John, u5081346en_AU
local.contributor.authoruidMaddess, Ted, u8103614en_AU
local.description.embargo2099-12-31
local.description.notesImported from ARIESen_AU
local.identifier.absfor111301 - Ophthalmologyen_AU
local.identifier.ariespublicationu4693331xPUB174en_AU
local.identifier.citationvolume94en_AU
local.identifier.doi10.1097/OPX.0000000000001022en_AU
local.identifier.scopusID2-s2.0-84996636558
local.identifier.thomsonID000395631200016
local.publisher.urlhttp://www.optvissci.com/en_AU
local.type.statusPublished Versionen_AU

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Pearce_Inter-visit_Test-retest_2017.pdf
Size:
307.92 KB
Format:
Adobe Portable Document Format