Abstract

Introduction Effective strategies to prevent hemodialysis (HD) catheter dysfunction are lacking and there is wide variation in practice. Methods In this post hoc analysis of the REDUcing the burden of dialysis Catheter ComplicaTIOns: a national (REDUCCTION) stepped-wedge cluster randomized trial, encompassing 37 Australian nephrology services, 6361 participants, and 9872 catheters, we investigated whether the trial intervention, which promoted a suite of evidence-based practices for HD catheter insertion and management, reduced the incidence of catheter dysfunction, which is defined by catheter removal due to inadequate dialysis blood flow. We also analyzed outcomes among tunneled cuffed catheters and sources of event variability. Results A total of 873 HD catheters were removed because of dysfunction over 1.12 million catheter days. The raw incidence was 0.91 events per 1000 catheter days during the baseline phase and 0.68 events per 1000 catheter days during the intervention phase. The service-wide incidence of catheter dysfunction was 33% lower during the intervention after adjustment for calendar time (incidence rate ratio = 0.67; 95% confidence interval [CI], 0.50–0.89; P = 0.006). Results were consistent among tunneled cuffed catheters (adjusted incidence rate ratio = 0.68; 95% CI, 0.49–0.94), which accounted for 75% of catheters (n = 7403), 97.4% of catheter exposure time and 88.2% of events (n = 770). Among tunneled catheters that survived for 6 months (21.5% of tunneled catheters), between 2% and 5% of the unexplained variation in the number of catheter dysfunction events was attributable to service-level differences, and 18% to 36% was attributable to patient-level differences. Conclusion Multifaceted interventions that promote evidence-based catheter care may prevent dysfunction, and patient factors are an important source of variation in events.

Description

Keywords

CVC, dialysis, malfunction, randomized, renal, variance

Citation

Source

Kidney International Reports

Type

Journal article

Book Title

Entity type

Access Statement

Open Access

License Rights

Creative Commons Attribution licence

Restricted until