Skip navigation
Skip navigation

Precision Spectroscopy in He as a test of QED

Bergeson, S; Balakrishnan, Asha; Lucatorto, T; Marangos, J; McIlrath, T; O'Brian, T; Rolston, S; Sansonetti, C; Werner, Helmut; Westbrook, N; Cheng, C; Eyler, Edward; Baldwin, Kenneth

Description

High-resolution laser-based measurements of energy levels have spurred the development and refinement of quantum electrodynamic calculations. We have extended very-high-resolution laser spectroscopy techniques into the vacuum ultraviolet wavelength region at λ ≈ 120 nm to determine the Lamb shift in the ground state of He I. The importance of this measurement to high accuracy quantum electrodynamics calculations is discussed. Details of the present measurement and future improvements are...[Show more]

dc.contributor.authorBergeson, S
dc.contributor.authorBalakrishnan, Asha
dc.contributor.authorLucatorto, T
dc.contributor.authorMarangos, J
dc.contributor.authorMcIlrath, T
dc.contributor.authorO'Brian, T
dc.contributor.authorRolston, S
dc.contributor.authorSansonetti, C
dc.contributor.authorWerner, Helmut
dc.contributor.authorWestbrook, N
dc.contributor.authorCheng, C
dc.contributor.authorEyler, Edward
dc.contributor.authorBaldwin, Kenneth
dc.date.accessioned2015-12-13T23:41:32Z
dc.date.available2015-12-13T23:41:32Z
dc.identifier.issn0031-8949
dc.identifier.urihttp://hdl.handle.net/1885/94955
dc.description.abstractHigh-resolution laser-based measurements of energy levels have spurred the development and refinement of quantum electrodynamic calculations. We have extended very-high-resolution laser spectroscopy techniques into the vacuum ultraviolet wavelength region at λ ≈ 120 nm to determine the Lamb shift in the ground state of He I. The importance of this measurement to high accuracy quantum electrodynamics calculations is discussed. Details of the present measurement and future improvements are presented.
dc.format.extent1 vol.
dc.format.mimetypeapplication/pdf
dc.language.isoen_AU
dc.publisherRoyal Swedish Academy of Sciences
dc.sourcePhysica Scripta
dc.titlePrecision Spectroscopy in He as a test of QED
dc.typeJournal article
local.description.notesImported from ARIES
local.description.refereedYes
local.identifier.citationvolume83
dc.date.issued1999
local.identifier.absfor020204 - Plasma Physics; Fusion Plasmas; Electrical Discharges
local.identifier.ariespublicationMigratedxPub24671
local.type.statusPublished Version
local.contributor.affiliationBergeson, S, Brigham Young University
local.contributor.affiliationBalakrishnam, A, SDL Inc.
local.contributor.affiliationBaldwin, Kenneth, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationLucatorto, T, National Institute of Standards and Technology
local.contributor.affiliationMarangos, J, Imperial College (London)
local.contributor.affiliationMcIlrath, T, American Physical Society
local.contributor.affiliationO'Brian, T, National Institute of Standards and Technology
local.contributor.affiliationRolston, S, National Institute of Standards and Technology
local.contributor.affiliationSansonetti, C, National Institute of Standards and Technology
local.contributor.affiliationWerner, Helmut, University of Wurzburg
local.contributor.affiliationWestbrook, N, Institut d'Optique
local.contributor.affiliationCheng, C, University of Connecticut
local.contributor.affiliationEyler, Edward, University of Connecticut
local.bibliographicCitation.startpage76
local.bibliographicCitation.lastpage82
dc.date.updated2015-12-12T09:32:56Z
local.identifier.scopusID2-s2.0-0141539041
CollectionsANU Research Publications

Download

There are no files associated with this item.


Items in Open Research are protected by copyright, with all rights reserved, unless otherwise indicated.

Updated:  17 November 2022/ Responsible Officer:  University Librarian/ Page Contact:  Library Systems & Web Coordinator