Skip navigation
Skip navigation

Performance of the Virgo interferometer longitudinal control system during the second science run

Accadia, T; Acernese, F; Beker, M G; Blom, M; Bosi, L; Colla, A; Genin, E; Huet, D; Rabeling, David; Ward, Robert

Description

The second science run of the Virgo gravitational wave interferometer took place between July 2009 and January 2010. This paper describes the performance of the interferometer longitudinal control system in terms of duty cycle, stability and control noise. A science data taking duty cycle of about 80% was obtained over the six month run. Control noise was not limiting the detector sensitivity at any frequency. A discussion of observed thermal effects in the detector operation is also included.

dc.contributor.authorAccadia, T
dc.contributor.authorAcernese, F
dc.contributor.authorBeker, M G
dc.contributor.authorBlom, M
dc.contributor.authorBosi, L
dc.contributor.authorColla, A
dc.contributor.authorGenin, E
dc.contributor.authorHuet, D
dc.contributor.authorRabeling, David
dc.contributor.authorWard, Robert
dc.date.accessioned2015-12-13T22:41:18Z
dc.date.available2015-12-13T22:41:18Z
dc.identifier.issn0927-6505
dc.identifier.urihttp://hdl.handle.net/1885/78444
dc.description.abstractThe second science run of the Virgo gravitational wave interferometer took place between July 2009 and January 2010. This paper describes the performance of the interferometer longitudinal control system in terms of duty cycle, stability and control noise. A science data taking duty cycle of about 80% was obtained over the six month run. Control noise was not limiting the detector sensitivity at any frequency. A discussion of observed thermal effects in the detector operation is also included.
dc.publisherElsevier
dc.sourceAstroparticle Physics
dc.subjectKeywords: Detector sensitivity; Duty cycles; Gravitational wave interferometers; Science-data; Stability and control; Control system stability; Control systems; Interferometers; Longitudinal control
dc.titlePerformance of the Virgo interferometer longitudinal control system during the second science run
dc.typeJournal article
local.description.notesImported from ARIES
local.identifier.citationvolume34
dc.date.issued2011
local.identifier.absfor020100 - ASTRONOMICAL AND SPACE SCIENCES
local.identifier.ariespublicationf5625xPUB7089
local.type.statusPublished Version
local.contributor.affiliationAccadia, T, Universite de Savoie
local.contributor.affiliationAcernese, F, INFN
local.contributor.affiliationBeker, M G, Nikhef
local.contributor.affiliationBlom, M, Nikhef
local.contributor.affiliationBosi, L, Universite Paris Diderot
local.contributor.affiliationColla, A, INFN
local.contributor.affiliationGenin, E, European Gravitational Observatory
local.contributor.affiliationHuet, D, European Gravitational Observatory
local.contributor.affiliationRabeling, David, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationWard, Robert, College of Physical and Mathematical Sciences, ANU
local.bibliographicCitation.issue7
local.bibliographicCitation.startpage521
local.bibliographicCitation.lastpage527
local.identifier.doi10.1016/j.astropartphys.2010.11.006
local.identifier.absseo970102 - Expanding Knowledge in the Physical Sciences
dc.date.updated2016-02-24T09:32:53Z
local.identifier.scopusID2-s2.0-78650953527
CollectionsANU Research Publications

Download

There are no files associated with this item.


Items in Open Research are protected by copyright, with all rights reserved, unless otherwise indicated.

Updated:  17 November 2022/ Responsible Officer:  University Librarian/ Page Contact:  Library Systems & Web Coordinator