Ultra-trace analysis of 36 Cl by accelerator mass spectrometry: An interlaboratory study

Merchel, S.; Bremser, W.; Alfimov, V.; Arnold, M.; Aumaitre, G.; Benedetti, L.; Bourles, D.L.; Caffee, M.; Fifield, L Keith; Finkel, Robert C; Freeman, S; Martschini, M.; Matsushi, Y.; Rood, D.H.; Sasa, K.; Steier, P; Takahashi, T.; Tamari, M.; Tims, Stephen; Tosaki, Y.; Wilcken, Klaus M.; Xu, S

Description

A first international36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with36Cl/Cl ratios at the 10-11, 10-12, and 10-13 level shows no difference in the sense of simple statistical significance. However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following...[Show more]

dc.contributor.authorMerchel, S.
dc.contributor.authorBremser, W.
dc.contributor.authorAlfimov, V.
dc.contributor.authorArnold, M.
dc.contributor.authorAumaitre, G.
dc.contributor.authorBenedetti, L.
dc.contributor.authorBourles, D.L.
dc.contributor.authorCaffee, M.
dc.contributor.authorFifield, L Keith
dc.contributor.authorFinkel, Robert C
dc.contributor.authorFreeman, S
dc.contributor.authorMartschini, M.
dc.contributor.authorMatsushi, Y.
dc.contributor.authorRood, D.H.
dc.contributor.authorSasa, K.
dc.contributor.authorSteier, P
dc.contributor.authorTakahashi, T.
dc.contributor.authorTamari, M.
dc.contributor.authorTims, Stephen
dc.contributor.authorTosaki, Y.
dc.contributor.authorWilcken, Klaus M.
dc.contributor.authorXu, S
dc.date.accessioned2015-12-10T23:35:57Z
dc.identifier.issn1618-2642
dc.identifier.urihttp://hdl.handle.net/1885/69949
dc.description.abstractA first international36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with36Cl/Cl ratios at the 10-11, 10-12, and 10-13 level shows no difference in the sense of simple statistical significance. However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that36Cl/Cl data from two individual AMS laboratories can differ by up to 17%. Thus, the demand for further work on harmonising the36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious.
dc.publisherSpringer
dc.sourceAnalytical and Bioanalytical Chemistry
dc.subjectKeywords: Accelerator mass spectrometry; Cosmogenic nuclides; Exposure dating; Interlaboratory comparison; Interlaboratory studies; Long-lived radionuclides; Reanalysis; Round Robin; Statistical significance; Ultra-trace analysis; Particle accelerators; Silver hali Accelerator mass spectrometry; Cosmogenic nuclides; Exposure dating; Long-lived radionuclides
dc.titleUltra-trace analysis of 36 Cl by accelerator mass spectrometry: An interlaboratory study
dc.typeJournal article
local.description.notesImported from ARIES
local.identifier.citationvolume400
dc.date.issued2011
local.identifier.absfor029904 - Synchrotrons; Accelerators; Instruments and Techniques
local.identifier.ariespublicationf2965xPUB2169
local.type.statusPublished Version
local.contributor.affiliationMerchel, S., Universite Aix-Marseille CEREGE
local.contributor.affiliationBremser, W., Federal Institute for Materials Research and Testing
local.contributor.affiliationAlfimov, V., ETH Zurich
local.contributor.affiliationArnold, M., Universite Aix-Marseille CEREGE
local.contributor.affiliationAumaitre, G., Universite Aix-Marseille CEREGE
local.contributor.affiliationBenedetti, L., Universite Aix-Marseille CEREGE
local.contributor.affiliationBourles, D.L., Universite Aix-Marseille CEREGE
local.contributor.affiliationCaffee, M., Purdue University
local.contributor.affiliationFifield, L Keith, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationFinkel, Robert C, Lawrence Livermore National Laboratory
local.contributor.affiliationFreeman, S, Scottish Universities Environmental Research Centre
local.contributor.affiliationMartschini, M., University of Vienna
local.contributor.affiliationMatsushi, Y., University of Tsukuba
local.contributor.affiliationRood, D.H., Lawrence Livermore National Laboratory
local.contributor.affiliationSasa, K., University of Tsukuba
local.contributor.affiliationSteier, P, University of Vienna
local.contributor.affiliationTakahashi, T., University of Tsukuba
local.contributor.affiliationTamari, M., University of Tsukuba
local.contributor.affiliationTims, Stephen, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationTosaki, Y., University of Tsukuba
local.contributor.affiliationWilcken, Klaus M., Scottish Universities Environmental Research Centre
local.contributor.affiliationXu, S, Scottish Universities Environmental Research Centre
local.description.embargo2037-12-31
local.bibliographicCitation.issue9
local.bibliographicCitation.startpage3125
local.bibliographicCitation.lastpage3132
local.identifier.doi10.1007/s00216-011-4979-2
dc.date.updated2016-06-14T08:35:03Z
local.identifier.scopusID2-s2.0-79958178834
local.identifier.thomsonID000291037800044
CollectionsANU Research Publications

Download

File Description SizeFormat Image
01_Merchel_Ultra-trace_analysis_of__36_Cl_2011.pdf294.24 kBAdobe PDF    Request a copy


Items in Open Research are protected by copyright, with all rights reserved, unless otherwise indicated.

Updated:  17 November 2022/ Responsible Officer:  University Librarian/ Page Contact:  Library Systems & Web Coordinator