Skip navigation
Skip navigation

Automatic Alignment system during the second science run of the Virgo interferometer

Accadia, T; Acernese, F; Antonucci, F; Astone, P; Ballardin, G; Barone, F; Barsuglia, M; Basti, A; Bauer, T.S.; Beker, M G; Rabeling, David

Description

In this paper the performances of the Automatic Alignment sensing and control system in the Virgo gravitational wave detector, during the second scientific run from July 7th 2009 to January 8th 2010, are described. The accuracy of the angular control loops fulfills the original Virgo requirements, reaching the accuracy of a few nano-radians for the most critical angular degrees of freedom, and the control noise is below the Virgo design sensitivity in the whole detection band.

CollectionsANU Research Publications
Date published: 2011
Type: Journal article
URI: http://hdl.handle.net/1885/61980
Source: Astroparticle Physics
DOI: 10.1016/j.astropartphys.2010.10.005

Download

There are no files associated with this item.


Items in Open Research are protected by copyright, with all rights reserved, unless otherwise indicated.

Updated:  17 November 2022/ Responsible Officer:  University Librarian/ Page Contact:  Library Systems & Web Coordinator