Determination of error field sources by accurate mapping of the magnetic geometry of the H-1 heliac
-
Altmetric Citations
Kumar, S T A; Blackwell, Boyd; Harris, Jeffrey H
Description
High precision mapping of the vacuum flux surfaces of the H-1NF heliac is carried out using electron-beam multi-wire tomography for various magnetic configurations and field strengths. The extreme accuracy of this technique has been exploited to understand the nature of error fields and to determine the best-fit empirical values for the H-1NF coil parameters, by point-by-point matching experimental surface data with computer modelling results. This has helped in developing a highly accurate...[Show more]
Collections | ANU Research Publications |
---|---|
Date published: | 2009 |
Type: | Journal article |
URI: | http://hdl.handle.net/1885/23735 |
Source: | Nuclear Fusion |
DOI: | 10.1088/0029-5515/49/3/035001 |