Investigation on reconstruction methods applied to 3D terahertz computed tomography

Recur, B; Younus, A; Salort, S; Mounaix, P; Chassagne, B; Desbarats, P; Caumes, J-P; Abraham, E


3D terahertz computed tomography has been performed using a monochromatic millimeter wave imaging system coupled with an infrared temperature sensor. Three different reconstruction methods (standard back-projection algorithm and two iterative analysis) have been compared in order to reconstruct large size 3D objects. The quality (intensity, contrast and geometric preservation) of reconstructed cross-sectional images has been discussed together with the optimization of the number of projections....[Show more]

CollectionsANU Research Publications
Date published: 2011-03-02
Type: Journal article
Source: Optics express