Measurement of As species in rice by HPLC-ICPMS after extraction with sub-critical water and hydrogen peroxide

dc.contributor.authorMaher, W. A.en
dc.contributor.authorEggins, S.en
dc.contributor.authorKrikowa, F.en
dc.contributor.authorJagtap, R.en
dc.contributor.authorFoster, S.en
dc.date.accessioned2026-01-01T15:41:57Z
dc.date.available2026-01-01T15:41:57Z
dc.date.issued2017-06-01en
dc.description.abstractA robust method for As speciation based on water-3% v/v hydrogen peroxide has been developed for use in laboratories undertaking rice analyses that gives equivalent results to the 2% v/v nitric acid extraction procedure that is widely used. Samples (0.2 g dry mass) were extracted with 9 mL of deionised water and 1 mL of 30% v/v hydrogen peroxide at 200 degrees C under 25 Bar using microwave heating in 100 mL Teflon-PFA vessels This has the advantage that all As(III) is converted to As(V) making quantitation using HPLC-ICPMS easier as the inorganic peak is moved away from any As cations in the void and the DMA peak that may interfere in quantitation of inorganic As. Recoveries of As in five rice reference materials and rice samples were 100 +/- 6% (n = 50) and 103 +/- 14% (n = 97) respectively. Comparison of the measurements of total As in extracts by ICPMS and ETAAS were also equivalent with no biases (y = 1.015 + 0.001, r(2) = 0.963, p < 0.0001) indicating that organic carbon extracted in rice extracts doesn't cause an enhancement of ICPMS signals There was no significant differences or biases in As speciation between the water-hydrogen peroxide and 2% v/v nitric acid procedures (y = 1.046 + 0.010, r(2) = 0.997, p < 0.0001). Typical reproducibility of rice samples (mean +/- 95% CI, n = 11) containing As concentrations at legislative limits are total As (0.192 +/- 0.004 mu g g(-1)), inorganic As (0.108 +/- 0.002 mu g g(-1)) and DMA (0.085 +/- 0.003 mu g g(-1)).en
dc.description.statusPeer-revieweden
dc.format.extent6en
dc.identifier.issn0267-9477en
dc.identifier.otherWOS:000403333100006en
dc.identifier.otherORCID:/0000-0002-9654-4015/work/167652758en
dc.identifier.scopus85021816308en
dc.identifier.urihttps://hdl.handle.net/1885/733801345
dc.language.isoenen
dc.sourceJournal of Analytical Atomic Spectrometryen
dc.subjectPlasma-mass spectrometryen
dc.subjectVolume microwave digestionen
dc.subjectArsenic speciationen
dc.subjectAciden
dc.subjectMsen
dc.subjectTissuesen
dc.subjectPlanten
dc.subjectChromatographyen
dc.subjectConsequencesen
dc.subjectVerificationen
dc.titleMeasurement of As species in rice by HPLC-ICPMS after extraction with sub-critical water and hydrogen peroxideen
dc.typeJournal articleen
dspace.entity.typePublicationen
local.bibliographicCitation.lastpage1134en
local.bibliographicCitation.startpage1129en
local.contributor.affiliationMaher, W. A.; University of Canberraen
local.contributor.affiliationEggins, S.; University of Canberraen
local.contributor.affiliationKrikowa, F.; University of Canberraen
local.contributor.affiliationJagtap, R.; University of Canberraen
local.contributor.affiliationFoster, S.; University of Canberraen
local.identifier.citationvolume32en
local.identifier.doi10.1039/c6ja00442cen