Reduction of Background Fluorescence from Impurities in Protein Samples for Raman Spectroscopy

dc.contributor.authorCorujo, Marco Pintoen
dc.contributor.authorMichal, Pavelen
dc.contributor.authorWesson, Roden
dc.contributor.authorAmarasinghe, Don Praveenen
dc.contributor.authorRodger, Alisonen
dc.contributor.authorChmel, Nikola P.en
dc.date.accessioned2025-06-24T07:38:50Z
dc.date.available2025-06-24T07:38:50Z
dc.date.issued2022-11-24en
dc.description.abstractBackground fluorescence remains the biggest challenge in Raman spectroscopy because of the consequent curvature of the baseline and the degradation of the signal-to-noise ratio of the Raman signal. While the concentrations of the fluorophore impurities are usually too low to be detected by other analytical methods, they are often sufficient to prevent Raman data collection. Among the different existing methods to remove the fluorescence signal, photobleaching remains the most popular due to its simplicity. However, using the spectrometer laser to photobleach is far from optimal. Most commercially available instruments have little or no choice of wavelength, and their output powers are in many cases not suitable for highly fluorescent samples such as those from biological systems (e.g., proteins). In this article, we assess practical aspects of photobleaching such as the apparent reversibility of the process and the effect of convection currents due to what we speculate to be temperature gradients across the bulk of the solution. We also introduce an affordable custom made external photobleaching unit with a choice of excitation wavelength and demonstrate its viability with a highly fluorescent bovine serum albumin protein solution, which had proved most challenging for Raman spectroscopy as it contained ∼10% w/w impurities.en
dc.description.statusPeer-revieweden
dc.format.extent8en
dc.identifier.issn2314-4920en
dc.identifier.otherORCID:/0000-0002-7111-3024/work/168398414en
dc.identifier.scopus85143404943en
dc.identifier.urihttp://www.scopus.com/inward/record.url?scp=85143404943&partnerID=8YFLogxKen
dc.identifier.urihttps://hdl.handle.net/1885/733764816
dc.language.isoenen
dc.rightsPublisher Copyright: © 2022 Marco Pinto Corujo et al.en
dc.sourceJournal of Spectroscopyen
dc.titleReduction of Background Fluorescence from Impurities in Protein Samples for Raman Spectroscopyen
dc.typeJournal articleen
dspace.entity.typePublicationen
local.contributor.affiliationCorujo, Marco Pinto; University of Warwicken
local.contributor.affiliationMichal, Pavel; Palacký University Olomoucen
local.contributor.affiliationWesson, Rod; University of Warwicken
local.contributor.affiliationAmarasinghe, Don Praveen; University of Warwicken
local.contributor.affiliationRodger, Alison; Macquarie Universityen
local.contributor.affiliationChmel, Nikola P.; University of Warwicken
local.identifier.citationvolume2022en
local.identifier.doi10.1155/2022/1928091en
local.identifier.pure65e99d41-9eaa-422c-9edd-1a4fa8bf0ed7en
local.identifier.urlhttps://www.scopus.com/pages/publications/85143404943en
local.type.statusPublisheden

Downloads