Sonicated Echocardiographic Contrast Agents: Reproducibility Studies

dc.contributor.authorFeinstein, Steven B.en
dc.contributor.authorKeller, Mark W.en
dc.contributor.authorKerber, Richard E.en
dc.contributor.authorVandenberg, Byronen
dc.contributor.authorHoyte, Johnen
dc.contributor.authorKutruff, Chrisen
dc.contributor.authorBingle, Jamesen
dc.contributor.authorFraker, Theodore D.en
dc.contributor.authorChappell, Richarden
dc.contributor.authorWelsh, Alan H.en
dc.date.accessioned2026-01-02T17:41:43Z
dc.date.available2026-01-02T17:41:43Z
dc.date.issued1989en
dc.description.abstractThis article describes the production, analysis, and reproducibility of forming microbubbles for contrast ultrasound imaging. The sonication method used to generate microbubbles was tested by four independent observers, and a subsequent laser particle counter analysis of microbubble size and concentration determined the reproducibility of the method. The results indicated that the mean bubble size was 3.3 ± 1.2 µm for the entire group, based on three trials of each of the four participants. The characteristics of the bubble size of the microbubbles between observers were assessed with a Poisson distribution with the reproducibility based on the sample mean for each observer's trials. Standardization and calibration of the laser particle counter was accomplished with commercially available latex spheres, sonicated albumin microspheres, and a Coulter counter analysis. Our results indicate that the sonication technique generates small microbubbles with a reproducible uniform size distribution. The method of microbubble production is reproducible and can be widely applied for use in contrast echocardiographic perfusion imaging of tissue in a variety of research and clinical studies. (J AM Soc ECHO 1989;2:125-31.)en
dc.description.sponsorshipFrom the Division of Cardiology' and Statistics/ University of Chicago, University ofVirginia/ University oflowa/ Methodist Hospital, Indianapolis/ University of Ohio,6 and Spectrex Corporation/ Redwood City. Supported in part by the Chicago Heart Association, Grant-inAid, Goldblart Research Foundation, and the Amoco Research Foundation. Reprint requests: Steven B. Feinstein, MD, The University of Chicago Hospital, Box 44, 5841 South Maryland Avenue, Chicago, IL 60637.en
dc.description.statusPeer-revieweden
dc.format.extent7en
dc.identifier.issn0894-7317en
dc.identifier.otherPubMed:2629861en
dc.identifier.scopus0024623864en
dc.identifier.urihttps://hdl.handle.net/1885/733802858
dc.language.isoenen
dc.sourceJournal of the American Society of Echocardiographyen
dc.titleSonicated Echocardiographic Contrast Agents: Reproducibility Studiesen
dc.typeJournal articleen
dspace.entity.typePublicationen
local.bibliographicCitation.lastpage131en
local.bibliographicCitation.startpage125en
local.contributor.affiliationFeinstein, Steven B.; The University of Chicagoen
local.contributor.affiliationKeller, Mark W.; The University of Chicagoen
local.contributor.affiliationKerber, Richard E.; University of Virginiaen
local.contributor.affiliationVandenberg, Byron; University of Virginiaen
local.contributor.affiliationHoyte, John; University of Iowaen
local.contributor.affiliationKutruff, Chris; Methodist Hospitalen
local.contributor.affiliationBingle, James; Ohio Universityen
local.contributor.affiliationFraker, Theodore D.; Ohio Universityen
local.contributor.affiliationChappell, Richard; The University of Chicagoen
local.contributor.affiliationWelsh, Alan H.; Spectrex Corpen
local.identifier.citationvolume2en
local.identifier.doi10.1016/S0894-7317(89)80075-6en
local.identifier.pure63bf3a50-38b5-42a8-a7df-13aa4e27466cen
local.identifier.urlhttps://www.scopus.com/pages/publications/0024623864en
local.type.statusPublisheden

Downloads